NEW QUESTION # 12
What is the recommended height of a ceiling in a data center or telecommunications room?

  • A. 012 ft
  • B. 0
  • C. 1015ft(correct)
  • D. 1112ft

Answer: C


NEW QUESTION # 13
What is the smoke development rating required for all materials hosted in a containment system?

  • A. 0
  • B. 1
  • C. 2
  • D. 3

Answer: D


NEW QUESTION # 14
According to TIA-942, what is the low temperature that must be maintained in a data center?

  • A. 65 degrees
  • B. 75 degrees
  • C. 68 degrees
  • D. 70 degrees
  • E. 60 degrees

Answer: C


NEW QUESTION # 15
Where should the entrance room be located within a data center?

  • A. In a separate building on the campus
  • B. Adjacent to or in a secured space within the computer room
  • C. Anywhere with easy access to the outside
  • D. In the computer room

Answer: B


NEW QUESTION # 16
What is the third preference regarding electricity supply?

  • A. At Least Two Circuits From Same Power Grid But Different Substations And Separate Paths
  • B. One Balanced Feeder Coordinated With Upstream Backup Feed
  • C. Two Balanced Feeds With Same Voltage Derived From A Single Distribution Station
  • D. One Circuit From Single Sub Station Fed Via Additional Path from Alternate Power Grid

Answer: A


NEW QUESTION # 17
what room should the battery room be adjacent to?

  • A. all
  • B. the electrical Room
  • C. Non-combustible materials
  • D. Mechanical Room
  • E. Security Rooms
  • F. computing Room

Answer: B

Explanation:
Explanation:


NEW QUESTION # 18
What's conservative' hydrogen maximum flow rate per minute for battery.

  • A. 61 cm/m²
  • B. 21 cm/m²
  • C. None of these answer
  • D. 500 cm/m²

Answer: B


NEW QUESTION # 19
When is a battery room required to have electrolyte spill containment and exhaust systems?

  • A. When the ceiling suspended load capacity is below 20 pounds per square foot
  • B. when the potential for outgassing hydrogen exists
  • C. When corrosive fumes are detected in operation room
  • D. when the battery weight exceeds 500 pounds

Answer: B


NEW QUESTION # 20
when is a battery room required to have electrolyte spill containment and exhaust systems?

  • A. when using Lithium batteries
  • B. All of Above
  • C. when the batteries contain liquid, free-flowing electrolyte
  • D. when using Sealed lead-acid-batteries
  • E. when using Nickel Cadmium batteries

Answer: C


NEW QUESTION # 21
What is the recommended placement of electrical distribution sub systems

  • A. install within server racks
  • B. none of the above
  • C. install within the computer room space on raised floor
  • D. install in dedicated electrical rooms, or, locate outside the computer room with fire rated wall

Answer: D

Explanation:
Explanation:


NEW QUESTION # 22
What level should the battery room be on?

  • A. Lower Floor
  • B. Grade Level
  • C. All
  • D. Upper floor
  • E. None

Answer: B


NEW QUESTION # 23
What is the most common type of automatic transfer switch?

  • A. Delayed transition
  • B. Soft load transition
  • C. Open transition
  • D. Closed transition

Answer: C


NEW QUESTION # 24
What are three reasons for locating the power distribution unit outside the computer room?

  • A. increases cooling efficiency, eliminates fire hazard, minimizes noise pollution
  • B. removes maintenance item, removes a source of heat, allows P D U to occupy less expensive space
  • C. reduces cable congestion, prevents water damage, provides better access points
  • D. lowers electricity costs, improves network speed, enhances security measures

Answer: B


NEW QUESTION # 25
What is the clearance required between cabinets and the perimeter wall?

  • A. 4 ft
  • B. 2 ft
  • C. 8 ft
  • D. 6 ft

Answer: A


NEW QUESTION # 26
What is the United States Average Power Utility Outage Annually And What Is The Average Repair Time?

  • A. Three outages annually, with an unknown average repair time
  • B. 1 outage annually, with average repair time of approximately eight hours
  • C. 1.86 outages annually, with average repair time of four hours
  • D. 2.5 outages annually, with average repair time of approximately 7 hours

Answer: C


NEW QUESTION # 27
According to NEB, what is the recommended range for the low temperature in a data center?

  • A. 55 degrees
  • B. 75 degrees
  • C. 70 degrees
  • D. 60 degrees
  • E. 65 degrees

Answer: E


NEW QUESTION # 28
......