2022 Latest DEA-41T1 dumps Exam Material with 120 Questions [Q66-Q87]

Share

2022 Latest DEA-41T1 dumps Exam Material with 120 Questions

EMC DEA-41T1 Questions and Answers Guarantee you Oass the Test Easily


The benefit of obtaining the Dell DEA-41T1: Associate - PowerEdge Exam Certification

  • Professionals accredited to Dell DEA-41T1 are more competitive and confident in the job market.
  • During the course of preparation of the Dell DEA-41T1 practice exams applicants will get knowledge of the installation, setup and maintenance of DELL EMC PowerEdge MX server product by using the DEE-4122 exam dumps and the Dell DEA-41T1 practice exams to enable professionalists achieve their skills.

EMC DEA-41T1 Exam Syllabus Topics:

TopicDetails
Topic 1
  • Explain the concept and benefits of server virtualization
  • Identify the types of servers and their form factors
Topic 2
  • Identify and explain common Dell Technologies and Microsoft Windows tools for monitoring server hardware
Topic 3
  • Explain the environment needed for servers and define server maintenance
  • Explain how various storage technologies are used in servers
Topic 4
  • Define Power supply of a server and configure it
  • Explain in RAID concepts
Topic 5
  • Identify the types of Server Operating Systems and explain the installation procedure

 

NEW QUESTION 66
Which protocol resolve IP address into MAC addresses?

  • A. DNS
  • B. STP
  • C. DHCP
  • D. ARP

Answer: D

 

NEW QUESTION 67
Refer to the exhibit.

An administrator has a standalone M1000e chassis with only a single CMC module. The CAT6 cable is plugged into the Ethernet port closest to the DB-9 connector. The power indicator light is lit but the administrator is unable to access the CMC module.
What could be the cause of this issue?

  • A. CAT5 cable is required for connection to CMC
  • B. CMC module was removed without powering off the chassis
  • C. No DB-9 serial cable is plugged in
  • D. CAT6 cable into the stacking port

Answer: C

Explanation:
Explanation/Reference:
Reference: https://topics-cdn.dell.com/pdf/poweredge-m1000e_owners-manual_en-us.pdf

 

NEW QUESTION 68
What is a consideration for a hardware administrator who is physically is physically installing multiple servers into a rack?

  • A. Ensure that the associated UPS can also power the top-of rack switch
  • B. Ensure that the server can connect to Windows updates
  • C. Observe load requirements specified in document for the switch
  • D. Avoid unevenly loading the rack and creating a hazard

Answer: C

 

NEW QUESTION 69
What is the object of server configuration management in an environment?

  • A. Maximum performance perwatt at all utilization levels and workload types while performance requirements.
  • B. Maximize server performance, regardless of workload, utilization or performance requirements
  • C. Reduce cost servers regardless of workload types, or performance requirements.
  • D. Minimize cost of server and to extend the lifetime of servers being used

Answer: A

 

NEW QUESTION 70
Where in the iDRAC GUI can the recording of the last three boot cycles of a Dell EMC PowerEdge server be found?

  • A. Troubleshooting > SupportAssist
  • B. Maintenance > Troubleshooting
  • C. Troubleshooting > Lifecycle Log
  • D. Maintenance > Diagnostics

Answer: B

 

NEW QUESTION 71
Which RAID level requires a minimum of four hard drives?

  • A. RAID 6
  • B. RAID 1
  • C. RAID 5
  • D. RAID 0

Answer: A

Explanation:
Explanation/Reference:
Reference: https://www.enterprisestorageforum.com/sans/features/article.php/3855631/RAID-Storage- Levels-Explained.htm

 

NEW QUESTION 72
A system administrator is configuring the file transfer role of a server. Important data needs to be accessed by end users.
Which file transfer service provides secure transfer of the data?

  • A. TFTP
  • B. FTP
  • C. SNMP
  • D. SFTP

Answer: D

 

NEW QUESTION 73
An administrator needs to set up a RAID which requires high performance but no data protection.
Which RAID level fulfills these requirements?

  • A. RAID 0
  • B. RAID 1
  • C. RAID 5
  • D. RAID 6

Answer: A

Explanation:
RAID 0 provides somewhat better performance than 5 or 1/10 but offers no data protection. In larger transfer size environments, RAID 1/10 performances can be slightly better than RAID 5 but has a much higher disk- cost.

 

NEW QUESTION 74
What is the maximum bootable storage capacity supported by BIOS mode?

  • A. 1 TB
  • B. 2 TB
  • C. 512 GB
  • D. 4 TB

Answer: B

 

NEW QUESTION 75
Which initial option should be chosen fromthe iDRAC Virtual Console to access System Setup?

  • A. Virtual CD/DVD
  • B. Normal Boot
  • C. Lifecycle Controller
  • D. Next Boot

Answer: C

 

NEW QUESTION 76
An administrator is implementing LTO-5 drives in the backup solution. They plan to disable hardware data compression through their backup appliance.
What is the maximum data rate that can be achieved?

  • A. 120 MB/s
  • B. 140 MB/s
  • C. 80 MB/s
  • D. 160 MB/s

Answer: B

 

NEW QUESTION 77
What is a benefit of having Uninterruptible Power Supply (UPS) attached to a server?

  • A. Replaces the need for power supplies in a server
  • B. Provides short-term protection to allow a server to be down gracefully
  • C. Provides permanent power to a server, eliminating the need for a wall outlet
  • D. Keeps a server running during a long power outage

Answer: B

 

NEW QUESTION 78
What is an accurate statement regarding 40 Gbps Ethernet ports?

  • A. Can be used as a single Gb connection or used as four 10 Gb connections
  • B. Must be segmented into four independent 10 Gb connections
  • C. Cannot be configure into a stack connection
  • D. May only be used as a non-negotiable single 40 Gb link

Answer: B

 

NEW QUESTION 79
A server room has two power grids, A and
B. PSU1 on each server is on grid A, and PSU2 is on grid B. Grid B has significantly lower load compared to grid A.
What is the most likely cause of the unbalanced power load?

  • A. UPS and PDU are not installed to balance the load
  • B. Hot spare feature is enabled in power supply configuration
  • C. PSU1 is always the primary power supply
  • D. PSU1 is a higher wattage power supply than PSU2

Answer: C

 

NEW QUESTION 80
Why is a mandatory practice to review the service manual prior to replacing or reseating components on a Dell EMC PowerEdge server?

  • A. Service manual gives detailed instructions at which firmware levels the components should run
  • B. Service manual describes how to reconfigure the server for optional performance-boosting settings, increasing efficiency
  • C. Service manual covers crucial cable routing and special part handling instructions
  • D. Service manual provides vital information on which live wires in the system to avoid, to ensure electric shock does not occur

Answer: C

 

NEW QUESTION 81
What is an statement in reference to software RAID?

  • A. Software RAID uses CPU resources
  • B. SoftwareRAID does not have any data integrity issues
  • C. Software RAID requires a hardware license
  • D. Software RAID is an additional cost

Answer: C

 

NEW QUESTION 82
Which types of data transfer interface are used by Dell EMC servers to connect mass storage devices?

  • A. Ethernet, SSD, CSI, CSI, and SAS
  • B. SSD, CSI, USB, and SAS
  • C. USB, Ethernet, SSD, and CSI
  • D. SAS USB, Ether, and SSD

Answer: D

 

NEW QUESTION 83
A network administrator has to reconfigure the company firewall to allow access to a website on the internet.
Which technology will provide the administrator with the correct IP address?

  • A. DNS
  • B. ARP
  • C. DHCP
  • D. HTTP

Answer: D

Explanation:
Explanation/Reference: https://www.forescout.com/company/resources/idrac-9-user-guide/ (55)

 

NEW QUESTION 84
What are the different types of event logs on a Windows server operating system?

  • A. Information, Warning, and Error
  • B. Information, Non Critical, and Critical
  • C. Healthy, Warning, and Critical
  • D. Healthy, Warning, and Important

Answer: A

 

NEW QUESTION 85
Which is an example of Host Channel Adapter?

  • A. InfiniBand PCI card
  • B. GPGPU PCIe card
  • C. An adapter that combines functionality of Ethernet and FC
  • D. PERC in PCIe adapter form factor with external connectors

Answer: A

Explanation:
Explanation/Reference: https://www.webopedia.com/definitions/host-channel-adapter/

 

NEW QUESTION 86
A server administrator needs to monitor a Dell EMC PowerEdge server without installing any additional software. Which management tool is the most appropriate to use?

  • A. OME
  • B. iDRAC
  • C. SAE
  • D. OMSA

Answer: A

 

NEW QUESTION 87
......

Share Latest DEA-41T1 DUMP Questions and Answers: https://learningtree.testkingfree.com/EMC/DEA-41T1-practice-exam-dumps.html